In vertical separators, a minimum diameter must be maintained to allow liquid drops to separate from the vertically moving gas. The liquid retention time requirement…
Category: Two Phase Separator Sizing
For sizing a horizontal separator it is necessary to choose a seam-toseam vessel length and a diameter. This choice must satisfy the conditions for gas…